ASTM D4417 METHOD C EBOOK DOWNLOAD

ASTM D – 11, “Standard Test Methods for Field Measurement of Surface locations and the arithmetic mean determined, Method C—A composite plastic. Designation: D – 03Standard Test Methods for Field Measurement of 3 Method C—A composite plastic tape is impressed into Method C—A These test methods are under the jurisdiction of ASTM Committee D01 on The sole. ASTM D – 11 Standard Test Methods for Field Measurement of Surface Profile 1 of 8 standard.3 Method C—A special tape3 containing a compressible 6.

Author: Gajin Malagrel
Country: Sierra Leone
Language: English (Spanish)
Genre: Photos
Published (Last): 7 March 2006
Pages: 334
PDF File Size: 13.6 Mb
ePub File Size: 12.16 Mb
ISBN: 829-4-17041-394-8
Downloads: 79603
Price: Free* [*Free Regsitration Required]
Uploader: Mezisho

The entire standard is being revised, and will include among other changes more specific operating procedures for the various types of test equipment. Steel is a fairly homogeneous substrate and its tensile strength does wstm vary from test site to test site. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and astm d4417 method c the applicability of regulatory limitations prior to use.

This is done because of evidence that coatings performance in any one small area is primarily astm d4417 method c by the highest surface features in that area and not by the average roughness.

Differences in Surface Profile Measurements: ASTM D4417- Method B vs. Method C

Referenced Documents astm d4417 method c separately The documents listed methos are referenced within the subject standard but are not provided as part of the standard. A test apparatus is attached to the loading fixture and aligned to pull perpendicularly. Since corrosion products expand as they migrate beneath a coating film, the coating astm d4417 method c disbond, leaving the substrate unprotected.

See Figures 45 and 6. Surface profile is defined as a measurement of the maximum peak-to-valley depth created by abrasive impingement against a surface during abrasive blast cleaning operations, or by an impact-type d4147 tool.

Currently, this subcommittee has eight task groups that are working on 13 ASTM standards, four of which are proposed standards and nine of which astm d4417 method c existing standards that have been slated for revision or renewal, or that have been recently published and require the development of precision and bias statements through interlaboratory research initiatives.

ASTM WKDraft Practice for Assessing the Concentration of Soluble Chlorides on Metallic Substrates, provides procedures for four methods of extracting a surface sample, four procedures for analyzing the collected sample for soluble chlorides, and one procedure for analyzing a collected sample for total dissolved salts conductivity.

Further, the tensile strength of steel far exceeds the tensile strength of an industrial protective coating. Models from a few gage manufacturers are available that conform to this standard.

Conceptually, the study will include two types of concrete normal and high strengthtwo coatings thick film with scoring and thin-film without scoringfive types of adhesion testers and up to seven laboratories. The standard describes the procedures for using and verifying the accuracy of portable stylus-type instruments to obtain surface characterization data, and provides guidance to the user regarding metgod significance of the data, once generated.

Data published in Appendix X1 of the standard generated astm d4417 method c an earlier interlaboratory research initiative reveals different pull-off strengths on four test specimens when using the various adhesion testers at that time, only four of the five testers that are in the current standard were astm d4417 method c in the research.

For example, requiring a 5. Historical Version s – view previous versions of standard. Once the surface profile pattern has been replicated into the tape, it is removed from the surface and placed in a special spring tension anvil micrometer. Many equipment manufacturers have developed loading fixtures with a larger surface area i. Coating manufacturers may also consider these requirements to improve the performance and the service life of the coatings astm d4417 method c supply.

The subcommittee develops and maintains standard test methods, practices and guides relating to the performance, evaluation, specification, application astm d4417 method c proper use of industrial protective coatings. See Figures 1314d417 DTest Astm d4417 method c for Pull-off Strength of Coatings Using Portable Adhesion Testers, has been developed to uniformly kethod coating adhesion astmm the laboratory, shop, or field.

Same Surface, Different Results?

Difference in Surface Profile Measurements: ASTM D Method B vs CKTA University

In this case, the minimum adhesion requirement becomes variable. Total of seven possible cleaning materials rather than five.

Historical Version s – view previous versions of standard Work Item s – proposed revisions of this standard Translated Version s: Further, when data are generated using different types of pull-off testers, it is difficult to compare astm d4417 method c tensile adhesion characteristics within a given generic coating category, or to compare the adhesion quality of different coating systems.

Without reliable methods for extracting a sample from the surface and analysis of the collected sample, the degree and type of surface cleaning required prior to coating astm d4417 method c can be uncertain. Leave a Reply Cancel reply Your email address will not be published. The decision whether to score has been left to the parties requiring the testing and those conducting it.

Evaluating graffiti resistance on freshly applied coating as astm d4417 method c as coating that has been artificially weathered in the laboratory. In fact, inASTM published DTest Methods for Measuring Surface Profile of Abrasive Blast Cleaned Steel, which describes three methods of quantifying surface profile depth generated in a steel substrate visual comparators, depth micrometers and replica tape.

As a result, a major revision to the standard was initiated in and continues today. An interlaboratory research initiative for the purpose of generating precision and bias statements for Dis planned for The four standards are: During abrasive blast cleaning, the mass of the abrasive and the velocity of the abrasive movement created by compressed air generates kinetic energy the abrasive can reach speeds of over astm d4417 method c per hour as it exits the blast nozzle.

Paint grade replica tape is used astm d4417 method c measure surfaces containing a profile from 1. While concrete has an impressive compressive strength often in excess of 28 Mpa psithe inherent tensile strength is only about 2. Early detection and mmethod of appreciable amounts of surface chloride contamination prior to coating installation can prolong the service life of a coating, reducing the frequency of maintenance painting and reducing life cycle costs.